Detector type: Photoelectric

Alarm Sound Level: 85 dB at 3 m (10 feet)
Frequency Band (MHz) - CE Listed PG4916: 433MHz; PG8916: 868MHz; FCC/IC/UL/ULC listed PG9916: 912-919 MHz Communication Protocol: PowerG
Tamper Alerts: Tamper event (removal of the unit from its bracket) is reported once. Tamper restore is reported when the tam- per switch is restored
Alarm Report: In the alarm condition, the detector sends the alarm event to the control panel. When the alarm condition is restored, the detector sends an alarm restore event to the control panel and sets the alarm restore indication (red LED blinks once per sec.). Note: The alarm restore indication can be cleared via the control panel only.
Power Source: 3 Volt CR123A consumer grade, UL listed Operation Voltage: From 2.5 V to 3 V.
Current Drain: 22 μA standby, 200 mA max. in operation
Smoke Density: Europe: 0.09 – 0.14 dB/m
USA: 1.44%/ft to 2.74%/ft
Cover Range :50 – 100 cubic meters (1770 – 3530 cubic ft.) Battery Supervision: Automatic transmission of battery status data as part of any transmitted message.
Low Battery Threshold: 2.5 V
Audible and Visual Low Battery Warning: Built-in horn beeps every 30 seconds simultaneously with red LED flashing (for up to 30 days when the battery voltage drops).
Audible and Visual Degraded Chamber Sensitivity Warning: Built-in horn beeps every 30 seconds in the middle of red LED flashing intervals – indicates that the detector must be replaced. Clean Warning Transmission: A clean (maintenance) signal is transmitted when the detector's chamber becomes stained, causing the detector to operate at high sensitivity.
Temperature range: -10°C to +55°C (UL/ULC verified 0° to +49°C)
Relative Humidity: max. 93%RH, non-condensing (UL/ULC ver- ified max 85%RH)
Dimensions: 120 mm (4.7") x 63 mm (2.5")

Compatible Receivers

433MHz Band: HSM2HOST4; HS2LCDRF(P)4;HS2ICNRF(P)4; PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC- NRF(P)8;PG8920

912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC- NRF(P)9; PG9920
Note: Only devices operating in band 912-919MHz are UL/ULC listed. 